![](images/bg04.gif) |
SCHURTER AG
|
Part No. |
CD41.4599.151
|
OCR Text |
...hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40... |
Description |
Power Entry Module; IEC; Voltage Rating: 250V; Current Rating: 6A; Terminal Type: Quick Connect Tabs; Fuseholder is accessible fromThe equipment front; IEC/EN 60979 6A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET
|
File Size |
764.17K /
4 Page |
View
it Online |
Download Datasheet
|
|
|
![](images/bg04.gif) |
SCHURTER AG
|
Part No. |
DD22.6321.1111 DD22.9121.1111
|
OCR Text |
...hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (1 min/50 hz) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front sid... |
Description |
DD22 POWER ENTRY MODULE W. FILTER 6A M5 6A, 250 VAC, MALE, MAINS POWER CONNECTOR, SOLDER FILTER, IEC, 10A, 2P SWITCH FUSE; Current rating:10A; Temp, op. max:85(degree C); Temp, op. min:-25(degree C) RoHS Compliant: Yes 10A, 250 VAC, MALE, MAINS POWER CONNECTOR, SOLDER
|
File Size |
666.62K /
5 Page |
View
it Online |
Download Datasheet
|
|
|
![](images/bg04.gif) |
SCHURTER AG SCHURTER INC
|
Part No. |
DD12.9121.111 DD12.9111.111 DD12.4111.111 DD12.1321.111 DD12.6111.111
|
OCR Text |
...hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (1 min/50 hz) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front sid... |
Description |
DD12 POWER ENTRY MODULE W. FILTER 10A 10A, 250VAC, MALE, MAINS POWER CONNECTOR, SOLDER DD12 POWER ENTRY MODULE W. FILTER 4A 4A, 250VAC, MALE, MAINS POWER CONNECTOR, SOLDER DD12 POWER ENTRY MODULE W. FILTER 1A M5 1A, 250VAC, MALE, MAINS POWER CONNECTOR, SOLDER DD12 POWER ENTRY MODULE W. FILTER 6A
|
File Size |
703.20K /
5 Page |
View
it Online |
Download Datasheet
|
|
|
![](images/bg04.gif) |
SCHURTER AG Advanced Monolithic Systems, Inc.
|
Part No. |
CD31.1501.151 CD61.1501.151 CDE4.4101.151 CDL4.4101.151 CD41.1501.151
|
OCR Text |
...hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40... |
Description |
Power Entry Module; IEC; Voltage Rating: 250V; Current Rating: 4A; Terminal Type: Quick Connect Tabs; Fuseholder is accessible fromThe equipment front; IEC/EN 60953 4A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET Power Entry Module; IEC; Voltage Rating: 250V; Current Rating: 10A; Terminal Type: Quick Connect Tabs; Fuseholder is accessible fromThe equipment front; IEC/EN 60955 10A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET Power Entry Module; IEC; Voltage Rating: 250V; Current Rating: 6A; Terminal Type: Quick Connect Tabs; Fuseholder is accessible fromThe equipment front; IEC/EN 60974 6A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET Power Entry Module; IEC; Voltage Rating: 250V; Current Rating: 10A; Terminal Type: Quick Connect Tabs; Fuseholder is accessible fromThe equipment front; IEC/EN 60975 10A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET Power Entry Module; IEC; Voltage Rating: 250V; Current Rating: 6A; Terminal Type: Quick Connect Tabs; Fuseholder is accessible fromThe equipment front; IEC/EN 60954 6A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET
|
File Size |
766.14K /
5 Page |
View
it Online |
Download Datasheet
|
|
|
![](images/bg04.gif) |
SCHURTER AG SCHURTER INC
|
Part No. |
DC22.2111.111 DC22.9123.111 DC22.1223.111 DC22.1111.111 DC22.1123.111 DC22.1221.111 DC22.2123.111 DC22.4121.111 DC22.4123.111 DC22.6123.111 DC22.2223.111 DC22.9221.111 DC22.9111.111 DC22.6111.111 SCHURTERINC-DC22.4123.111
|
OCR Text |
...hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40... |
Description |
Switched IEC Power Connector; Voltage Rating:250V; Mounting Type:Panel; Terminal Type:Thru Hole Pins; Current Rating:2A; Approval Bodies:UL RoHS Compliant: Yes 2A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER Switched IEC Power Connector; Voltage Rating:250V; Mounting Type:Panel; Terminal Type:Thru Hole Pins; Current Rating:10A; Approval Bodies:UL RoHS Compliant: Yes 10A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER Switched IEC Power Connector; Voltage Rating:250V; Mounting Type:Panel; Terminal Type:Thru Hole Pins; Current Rating:1A; Approval Bodies:UL RoHS Compliant: Yes 1A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER Switched IEC Power Connector; Voltage Rating:250V; Mounting Type:Panel; Terminal Type:Thru Hole Pins; Current Rating:4A; Approval Bodies:UL RoHS Compliant: Yes 4A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER Switched IEC Power Connector; Voltage Rating:250V; Mounting Type:Panel; Terminal Type:Thru Hole Pins; Current Rating:6A; Approval Bodies:UL RoHS Compliant: Yes 6A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER
|
File Size |
734.81K /
5 Page |
View
it Online |
Download Datasheet
|
|
|
![](images/bg04.gif) |
SCHURTER AG
|
Part No. |
GRM2.1180.013
|
OCR Text |
... hz dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40... |
Description |
Power Entry Module; IEC; Voltage Rating: 250V; Current Rating: 10A; Terminal Type: Quick Connect Solder Tabs; Ultra-compact design; "lock and in-in design; IEC/EN 60950 10A, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET
|
File Size |
401.73K /
3 Page |
View
it Online |
Download Datasheet
|
|
|
![](images/bg04.gif) |
Advanced Power Electronics, Corp. SCHURTER AG
|
Part No. |
CG10.6101.151 CG30.6101.151 CGL0.6101.151
|
OCR Text |
...hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40... |
Description |
Power Entry Module; IEC; Voltage Rating: 250V; Current Rating: 1A; Terminal Type: Quick Connect Tabs; "Extra-Safe" fuse drawers; single element are already partial wired 1A, 250/125VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET Power Entry Module; IEC; Voltage Rating: 250V; Current Rating: 4A; Terminal Type: Quick Connect Tabs; "Extra-Safe" fuse drawers; single element are already partial wired 4A, 250/125VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET Power Entry Module; IEC; Voltage Rating: 250V; Current Rating: 10A; Terminal Type: Quick Connect Tabs; "Extra-Safe" fuse drawers; single element are already partial wired 10, 125/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET
|
File Size |
816.39K /
5 Page |
View
it Online |
Download Datasheet
|
|
|
![](images/bg04.gif) |
![PS9814-1 PS9814-1-A PS9814-1-F3 PS9814-1-F3-A PS9814-1-F4 PS9814-1-F4-A PS9814-1-V PS9814-1-V-A PS9814-1-V-F3 PS9814-1-V](Maker_logo/california_eastern_labs.GIF)
California Eastern Labs
|
Part No. |
PS9814-1 PS9814-1-A PS9814-1-F3 PS9814-1-F3-A PS9814-1-F4 PS9814-1-F4-A PS9814-1-V PS9814-1-V-A PS9814-1-V-F3 PS9814-1-V-F3-A PS9814-1-V-F4 PS9814-1-V-F4-A PS9814-2 PS9814-2-A PS9814-2-F3 PS9814-2-F3-A PS9814-2-F4 PS9814-2-F4-A PS9814-2-V PS9814-2-V-A PS9814-2-V-F3 PS9814-2-V-F3-A PS9814-2-V-F4 PS9814-2-V-F4-A
|
OCR Text |
... 20 10 3 50 60 kV/s 51 VI-O = 1 kvdc, RH = 40 to 60%, TA = 25C VI-I = 1 kvdc, RH = 40 to 60%, TA = 25C V = 0 V, f = 1 MHz, TA = 25C 1011 1010 0.6 0.3 54 75 100 75 100 ns pF IFHL VCC = 5 V, VO = 0.8 V, RL = 350 ICCL VCC = 5.5 V , IF = 10 m... |
Description |
HIGH CMR, 10 Mbps OPEN COLLECTOR OUTPUT TYPE 8-PIN SSOP (SO-8) HIGH-SPEED OPTOCOUPLER
|
File Size |
434.33K /
12 Page |
View
it Online |
Download Datasheet
|
|
![](images/findchips_sm.gif)