TELE FILTER tft GmbH
Measurement condition Ambient temperature: Input power level: Source impedance: Load impedance: Ext coil: Construction see page 2 Characteristics Remark:
SAW filter specification
TFS 246 H
1/4
______________________________________________________________________________________________________
23 C 0 dBm 490 || -2.62 pF ( 10%) 490 || -2.62 pF ( 10%) 82 nH
Reference level for the relative attenuation arel of the TFS 246 H is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 246 H MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo.
Data
typ. value
tolerance / limit
______________________________________________________________________________________________________ 2,5 dB max 5 dB ae = amin Insertion loss (Reference level) ______________________________________________________________________________________________________ 246,000 MHz fN Nominal frequency ______________________________________________________________________________________________________ Pass band ripple fN - 85 kHz ... fN + 93 kHz max 1,5 dB ______________________________________________________________________________________________________ Relative attenuation arel 246,0 MHz 120 kHz 1,5 dB max 3 dB
246,0 MHz 330 kHz ... 246,0 MHz 400 kHz 22 dB min 18 dB 246,0 MHz 400 kHz ... 246,0 MHz 600 kHz 33 dB min 25 dB 246,0 MHz 600 kHz ... 246,0 MHz 800 MHz 50 dB min 40 dB 246,0 MHz 800 kHz ... 246,0 MHz 1,6 MHz 55 dB min 45 dB 246,0 MHz 1,6 MHz ... 246,0 MHz 3,0 MHz 55 dB min 45 dB 246,0 MHz 3,0 MHz ... 246,0 MHz 20 MHz 55 dB min 46 dB 246,0 MHz 20 MHz ...246,0 MHz 100 MHz 55 dB min 45 dB ______________________________________________________________________________________________________ GDD Group delay distortion 246,0 MHz 50 kHz 0,5 s max 1,2 s 246,0 MHz 70 kHz 0,8 s max 1,5 s 246,0 MHz 100 kHz 1,2 s max 2,5 s ______________________________________________________________________________________________________ Operating temperature range - 20 C ... + 70 C Storage temperature range - 30 C ... + 85 C ______________________________________________________________________________________________________ - 0,036 ppm/K Temperature coefficient of frequency TCf ______________________________________________________________________________________________________ Frequency inversion temperature + 25 C ______________________________________________________________________________________________________
Generated: Checked / approved:
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS246H.eng
version1.1
06.01.02
______________________________________________________________________________________________________
TELE FILTER tft GmbH
SAW filter specification
TFS 246 H
2/4
______________________________________________________________________________________________________
Construction and pin configuration (All dimensions in mm)
S 246 H L4
1 Output
2 Output
3 Ground 4 ext. Coil
5 Ground 6 Ground 7 Input 8 Input
9 Ground 10 Ground 11 Ground 12 Ground
50 Ohm Test circuit 1
LB-IN L1 8 1 L2 LB-OUT
C1
SAW
7 4 3,5,6,9,10,11,12 L5 2
C2
L3
L4
50 Ohm Test circuit 2
LB-IN C1 8 1 C2 LB-OUT
L1
SAW
7 2 4 L3
L2
C3
C4
3,5,6,9,10,11,12
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS246H.eng
version1.1
06.01.02
______________________________________________________________________________________________________
TELE FILTER tft GmbH
SAW filter specification
TFS 246 H
3/4
______________________________________________________________________________________________________
Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 30g, 18 ms, half sine wave, 3 shocks each plane; IEC 68 - 2 - 27 10 Hz to 150 Hz, 0.35 mm amplitude, 5g; 2 hours for 3 planes; IEC 68 - 2 - 6 90 % to 95 % rel. humidity, 40 C, 10 days; IEC 68 - 2 - 3
2. Vibration:
3. Damp heat:
4. Resistance to solder heat (Reflow):
260 C for 10 sec;
Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 3400
Tape (all dimensions in mm) W Po Do D1 E : : : : : 16 4 1,5 1,5 0,3 0,1 + 0,5 + 0,5
EMBOSSED CARRIER TAPE
Do
Po
P2
E Ao F W
1,75 0,1 7,5 0,1 0,75 2 8 1,5 5,4 7,4 0,05 0,1
P1 13,4
0,1
F : G (min) : P2 P1 : :
D1 Bo
G
D1(min) : Ao : Bo :
0,1 0,1
COVER TAPE
W2
Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 16,4 +2 22,4 >= 90
C A N
13
0,25
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape.
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS246H.eng
version1.1
06.01.02
______________________________________________________________________________________________________
TELE FILTER tft GmbH
SAW filter specification
TFS 246 H
4/4
______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS246H

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X